02.05
6 Wiring
© Siemens AG 1998 All Rights Reserved
FM-STEPDRIVE/SIMOSTEP (FB)
6-7
6.4
Network wiring for several axes
FM-STEPDRIVES
DC
+
DC
-
115
230
N
PE
MS
DC
+
DC
-
115
230
N
PE
MS
DC
+
DC
-
115
230
N
PE
MS
Mains
filter
L
N
PE
Mains filter types:
for 115 V = B84142-B16-R for 2 axes max.
for 230 V = B84142-B16-R for 3 axes max.
Figure 6-6 Multi-axis wiring with single-phase mains connection
Note
The intermediate circuit connections (DC+ and DC-) can be inter-
connected for energy exchange between the power controllers if
considerable masses must be accelerated and decelerated within a
short time.
Note
The mains connection cables must be shielded on both ends.