![Siemens Mobile TC45 Manual Download Page 432](http://html.mh-extra.com/html/siemens-mobile/tc45/tc45_manual_1266136432.webp)
TC45 AT Command Set
18.5 AT^SJNET
s
m
obile
TC45_ATC_V02.02
Page 432 of 461
4/16/04
Confidential / Released
Parameter specifies the login name for access to the dialup network
Parameter is global for all interfaces, volatile and will not be reset by
““
(P)
Parameter specifies the password for access to the dialup network
Parameter is global for all interfaces, volatile and will not be reset by
““
(P)
Parameter specifies the Primary DNS server (Nameserver) for the dialup network. The server address has to
be specified in dotted IP address format (e.g. 145.146.147.148). If parameter is omitted, then it will be assumed,
that a name server is not available.
Parameter is global for all interfaces, volatile and will not be reset by
““
(P)
Idle Timeout
Parameter specifies the java network idle timeout, which is the time period in seconds after which the network
connection is terminated automatically when no data transfer or other network activities take place. The value
0 means no timeout at all (you have to terminate a Circuit Switched Data connection using
and a GPRS
connection using
=0).
We recommend to use values greater than 10 seconds because otherwise you may get unintentional timeouts
for slow network connections.
Parameter is global for all interfaces, volatile and will not be reset by
0
(P)
...[30]...21600
Example
This example illustrates how to configure a profile for circuit switched network access: The dialup phone number
is +49800654321, user name is "user1", password is "dialup123", and the primary DNS has IP address
"145.146.147.148".
<login>
(str)(+CSCS)
<password>
(str)(+CSCS)
<dns>
(str)(+CSCS)
<timeout>
(num)
AT^SJNET="CSD", "+49800654321", "user1", "dialup123", "145.146.147.148"
^SJNET: "csd","+49800654321","user1","dialup123","145.146.147.148",30
OK