14
AEROMAT VT
Installation and operating instructions
Last update: 02.2015
Technical data
Specifications for a VT unit
DSg Type
DS Type
RS Type
Sound absorption
(at 300 mm installation depth)
1) 5)
R
w-1.9
= 33 - 49 dB
D
n,e,w
= 40 - 56 dB
R
w-1.9
= 50 dB
D
n,e,w
= 57 dB
R
w-1.9
= 50 dB
D
n,e,w
= 57 dB
Max. permissible area load per linear
metre of ventilator length
1,000 kg
1,000 kg
1,000 kg
Heat transition coefficient
2)
U = 0.25 W/m
2
K
U = 0.25 W/m
2
K
U = 0.25 W/m
2
K
Air throughput
5)
approx. 16 - 66 m
3
/h
(at 10 Pa)
approx. 16 m
3
/h
(at 10 Pa)
Air throughput
measured via membrane key
3)
-
-
Level 1 = approx.30 m
3
/h
Level 2 = approx.50 m
3
/h
Internal noise at blower level 1
4) 6)
-
-
L
pA
= approx. 14 dB(A)
Internal noise at blower level 2
4) 6)
-
-
L
pA
= approx. 26 dB(A)
Supply voltage
-
-
230 V
∼
Unit operating voltage
-
-
24 V
Power consumption at blower level 1
-
-
approx. 5 Watt
Power consumption at blower level 2
-
-
approx. 17 Watt
Protection class
-
-
II
Power supply
-
-
230 V
∼
/ 50 Hz
Safety device
-
-
Thermal protection in
transformer
Length of connecting cable
-
-
Approx. 1.50 m or 5 m
1)
measured according to DIN EN 20140-10
2)
calculated according to DIN EN ISO 6946.
3)
measured according to DIN EN ISO 5167
4)
measured according to EN ISO 9614-2:1996 (with room insulation of 8 dB).
5)
depending on the number of air canals
6)
with exhaust air units internal sound increases by approx. 3 dB (A)
Dimensions
Specifications for a VT unit
DSg Type
DS Type
RS Type
Ventilator length (LL)
600 mm to 3,000 mm
600 mm to 3,000 mm
725 mm to 3,000 mm
Installation depth (BT)
250 mm to 500 mm
250 mm to 500 mm
300 mm to 500 mm
Summary of Contents for AEROMAT VT.