Installation and operating instructions
AEROMAT VT
Last update: 02.2015
13
AEROMAT VT (DSg Type)
Note:
The number and position of the components can deviate from the illustration.
1. Remove the front panel (see page 12)
2. Remove air canal/foam elements and clean or replace
3. Reassemble the AEROMAT VT in the reverse order
AEROMAT VT (DS and RS Type)
Note:
The number and position of the components can deviate from the illustration.
1. Pull out the mains plug or switch off the safety device for the power supply cable
2. Remove the front panel (see page 12)
3. Remove front profile insulation and filter
4. Remove the foam
5. Remove the supporting plate, to do this, press the top toward the interior of the unit and pull out of the bottom
6. Open the transformer compartment and release the blower cable from the circuit board
7. Carefully take out the air canal/foam element and remove the blower
8. If necessary, clean the blower using compressed air only
9. Insert blower in the new air canal
10. Reassemble the AEROMAT VT in the reverse order
2.
4.
5.
7.
3.
with flap tr
ap
with internal electr
ical closer
Foam insulation
G3 / M5 F
ilter
Front profile insulation
(DS)
Exhaust air (RS)
Supply air (RS)