4
5
6
Figure 6: Second point determination
If two points on the tool’s Z axis lie within the WFZ’s crossing point, the tool is not only cen‐
trally aligned but also perpendicular to the WFZ.
Figure 7: Correct positioning in the crossing point, perpendicular to the WFZ
2
Teach-in function
Route pin 5 and gray cable to + (L+) for > 1 s. The yellow LEDs flash during the teach-in
procedure.
NOTE
For maximum accuracy, we recommend using the teach-in function before every measure‐
ment. At least, however:
•
after initial commissioning of the sensor
•
after cleaning
•
if the light beams display a weak signal, even though the light path is clear
3
PNP (Load
→
M): light path free, output (Q) high
7
Troubleshooting
The Troubleshooting table indicates measures to be taken if the sensor stops working.
7
TROUBLESHOOTING
10
8023382.14JZ | SICK
Subject to change without notice