1
General safety notes
■
Read the operating instructions before commissioning.
■
Connection, mounting, and adjustment may only be performed by trained
specialists.
■
2006/42/EC
NO
SAFETY
Not a safety component in accordance with the EU Machinery Directive.
■
When commissioning, protect the device from moisture and contamination.
■
These operating instructions contain information required during the life cycle of
the sensor.
■
The radiation of the emitted light must not be focused by additional optical
devices.
EN/IEC 60825-1:2014
IEC60825-1:2007
LASERKLASSE 1
Laser
1
Maximum pulse power < 2,5 mW
Puls length: 4 µs
Wavelength: 650 - 670 nm
Complies with 21 CFR 1040.10
and 1040.11 except for deviations
pursuant to Laser Notice No. 50,
dated June 24, 2007
ATTENTION
WARNING: Interruption, manipulation or incorrect use can lead to hazardous exposure
due to laser radiation.
2
Intended use
The WFZ through-beam photoelectric sensor consists of two opto-electronic sender and
receiver units. The respective sender and receiver units are arranged crosswise so that
objects in the center of the crossing point can be positioned using signals from both
switching outputs (Q1 + Q2). The WFZ is used for the optical, non-contact detection and
positioning of objects.
GENERAL SAFETY NOTES
1
8023382.14JZ | SICK
Subject to change without notice
5