6
COMMISSIONING
46
8025140/2020-02-03|SICK
T R A N S L A T I O N O F T H E O R I G I N A L O P E R A T I N G I N S T R U C T I O N S | VMS6200
Subject to change without notice
•
Limit the list to the LMS500 family and click
Next
to confirm.
Click
Next
to confirm each of the configured search settings, and click
Finish
to
complete.
If the number ranges for the configuration PC and the device correspond, then the
connected volume measurement device is detected and displayed in the device list on the
right-hand side.
NOTE!
The volume measurement device (like all SICK devices) uses two ports. Ports are
part of the network address and can be used to establish various connections between
the devices. Port
2112
is freely configurable but port
2111
is a fixed port for outputting
data. It is used for device configuration.