5.2
Connection to the voltage supply
Fig. 24: Pin assignment of the -X100 terminal block in the cabinet
Terminal
Color
Signal Function
-X100/1.1
Gray
L
Line voltage 100…264 V AC /
50…60 Hz (phase)
-X100/1.4
Blue
N
Line voltage 100 ... 264 V AC /
50 ... 60 Hz (neutral conductor)
-X100/1.6
Green-
yellow
PE
Protective conductor
Tab. 1: Pin assignment of the -X100 terminal block in the cabinet
NOTE!
▸
Make sure that cables are securely connected.
No visible metal surfaces are permitted on the wires.
▸
Tighten the coupling nuts to provide strain relief on the cabinet. Doing so also
maintains the enclosure rating.