Mounting
Minimum distance calculation:
•
Step 1: Calculation of the stopping/run-down time of the entire system:
T = 290 ms + 20 ms = 310 ms = 0.31 s
•
Step 2: Insert the values in the 1st formula (S = 2000 × T + 8 × (d – 14)):
S = 2000 × 0.31 + 8 × (20 – 14) = 668 mm
•
Step 3: Check the value for S.
S > 500 mm. For this reason the 2nd formula must be used.
•
Step 4: Insert the values in the 2nd formula (S = 1600 × T + 8 × (d – 14)):
S = 1600 × 0.31 + 8 × (20 – 14) = 544 mm
•
Step 5: Check the value of S.
S > 500 mm. For this reason 544 mm must be used as the minimum distance.