5
Signal IN X
Posi‐
tion
Signal
TiM3xx-01xxxx
(cable with flying
leads): wire color
TiM3xx-10xxxx (15-pin D-
Sub-HD male connector):
PIN
TiM3xx-11xxxx,
TiM3xx-21xxxx (12-pin
M12 male connector): PIN
A
V
S
Red
1
2
B
V
IN
White + black
15
9
D
GND
Black
5
1
C1
IN 1
Turquoise or light
gray
8
3
C2
IN 2
Green
9
4
C3
IN 3
Gray
10
10
C4
IN 4
Pink
11
11
Switching behav‐
ior
Current to the input starts the assigned function in the device.
Default: Active high level, debounce 10 ms
Properties
Opto-decoupled
Switchable with an electronic switch (PNP output) or mechanical switch
Electrical values
Low: V
in
≤
2 V; I
in
≤
0.3 mA
High: 8 V
≤
V
in
≤
32 V; 0.7 mA
≤
I
in
≤
5 mA
Digital outputs
The device has 4 switching digital outputs.
In combination, the digital outputs OUT 1 to OUT 3 signal the breach of the individual
fields of a field set.
The digital output OUT 4 is used to issue an error and a regular index pulse.
The structure and wiring principle of the digital outputs are shown below.
Device
1
OUT X
2
X
Y
GND
V
out
3
4
Figure 28: Wiring of digital output (PNP version)
1
Device
2
Signal OUT X
3
Output voltage V
out
4
If an inductive load is present: Provide an arc-suppression circuit at the digital switching
output. Attach a freewheeling diode directly to the load for this purpose.
Posi‐
tion
Signal
TiM3xx-01xxxx
(cable with flying
leads): wire color
TiM3xx-10xxxx (15-pin D-
Sub-HD male connector):
PIN
TiM3xx-11xxxx,
TiM3xx-21xxxx (12-pin
M12 male connector): PIN
X1
OUT 1
Brown
12
5
X2
OUT 2
Orange
13
6
6
ELECTRICAL INSTALLATION
38
O P E R A T I N G I N S T R U C T I O N S | TiM3xx
8024851//2021-07-21 | SICK