The safety laser scanner must be arranged and configured in such a manner that
it can detect objects entering into the hazardous area.
•
The optical path of the safety laser scanner must be kept clear at all times and
must also not be obscured by transparent objects such as protective screens, plex‐
iglass, lenses, etc. The protective function of the safety laser scanner can only be
guaranteed if the contamination measurement function is not circumvented by
such measures.
Further topics
•
•
3.2
Product characteristics
3.2.1
Specific features
•
180° scanning angle
•
Increased dust and particle tolerance due to dazzle and particle algorithms
•
Protective field range: 7 m
•
Warning field range: 49 m (20 m at 20% radiance factor)
•
Configuration via PC or notebook using the SICK Configuration & Diagnostic soft‐
ware
•
Dual field mode with field sets comprising a protective field and a warning field
(optional simultaneous monitoring of 2 field sets)
•
Dual protective field mode with field sets comprising 2 protective fields (optional
simultaneous monitoring of 2 field sets = 4 protective fields)
•
Triple field mode with field sets comprising one protective field and 2 warning
fields
•
Contour monitoring of a protective field
•
•
Integrated external device monitoring (EDM)
•
Integrated configurable restart interlock/restart delay
•
Secure bus connection via Enhanced Function Interface (EFI) for operation in a
system network with other safety laser scanners, with products in the sens:Control
product group, or with a Flexi Soft safety controller
•
Compatibility mode for interoperability with older generation safety laser scanners
•
Minimum response time: 60 ms
•
Secure bus connection via sens:Control products from SICK
•
Extended temperature range: –30 °C to 50 °C
•
Up to 4 field sets
•
Monitoring case switching via static inputs or EFI
The S3000 Cold Store has been specially designed for cold stores. It can be used within
an ambient temperature range of –30 °C to +50 °C.
The device fulfills the requirements of enclosure rating IP67 according to EN 60529
and is equipped with an internal, thermostat-controlled heater. This heater switches
itself on when required. The safety laser scanner is operational once the required tem‐
perature inside the housing is reached. The heater automatically switches itself on dur‐
ing operation when required (cyclical heating).
PRODUCT DESCRIPTION
3
8012029/ZA20/2019-11-14 | SICK
O P E R A T I N G I N S T R U C T I O N S | S3000 Cold Store
15
Subject to change without notice