Chapter
3
Technical Information
RFID write/read device RFH630 (HF)
10
©
SICK AG · Germany · All rights reserved · Subject to change without notice
8014957/YSU6/2016-01-08
Electrical installation
Using the data interfaces
RFH630-1102101
RFH630-1000001
Possible interface
HOST 1
AUX 1
HOST 2
AUX 2
Assignable function
RS-232/422 RS-232
Ethernet
Ethernet
Read result output (format 1)
Read result output (format 2)
Read diagnosis output (fixed format)
Monitoring of HOST interface traffic
Configuration (SOPAS, commands)
= Output of the same function simultaneously possible via the interfaces
= Access only makes practical sense via one of the interfaces (risk of collision)
Possible interface
HOST
AUX
Assignable function
RS-232/422 RS-232
Read result output (format 1)
Read result output (format 2)
Read diagnosis output (fixed format)
Monitoring of HOST interface traffic
RFH630-1000001
Aux (e.g. configuration)
RS-232
SOPAS
CAN
Host (e.g. data output)
PC
RS-232
*)
RS-422
*)
*)
Select on of the two interfaces.
RFH630-1102101
Aux 1 (e.g. configuration)
RS-232
SOPAS
CAN
Ethernet
Aux 2 (e.g. configuration)
Host 1 (e.g. data output)
Host 2 (e.g. data output)
PC
RS-232
*)
RS-422
*)
*)
Select on of the two interfaces.