Configuration with command strings
•
Dimensional drawings of the accessories
•
Supplementary documentation (overview)
•
Copy of EC Declaration of Conformity
11.2
Configuring the interrogator with command strings
As an alternative to the SOPAS-ET configuration software, the interrogator can also be con-
figured and operated with command strings via all the data interfaces. The command
strings can be displayed separately via the SOPAS-ET configuration software.
Important
Both the command strings and the SOPAS-ET configuration software are based on com-
mand language which directly accesses the command interpreter of the interrogator. This
command language must be used with care as the interrogator executes sent commands
immediately. Parameter values altered via commands are, at first, only active in the current
parameter set in the working memory (RAM) of the interrogator. To save in the permanent
memory, the altered parameter set must be copied into the PROM using a special com-
mand; this ensures that the alterations are not lost when the power supply is switched off.
Command strings for triggering the reading pulse:
•
START: <STX>sMN mTCgateon<ETX>
•
STOP: <STX>sMN mTCgateoff<ETX>
If the commands are entered via the terminal emulator of the SOPAS-ET configuration soft-
ware, the two control characters <STX> and <ETX> are omitted.
Connection to the interrogator using the terminal emulator via the Ethernet:
1. Call up the terminal emulator via the menu
TOOLS
/
TERMINAL
of the SOPAS-ET configura-
tion software and, in the terminal emulator, call up the connection assistant via the
menu
SET
UP
CONNECTIONS
/
CONNECTION
.
2. Select the option
USER
-
DEFINED
CONNECTION
in the connection assistant and confirm by
pressing
NEXT
.
3. Select the option TCP/IP and confirm by pressing
NEXT
.
4. Select the option
SHOW
ONLY
C
O
L
A
TELEGRAMS
.
5. Enter the interrogator's IP address in the relevant field and confirm by pressing
NEXT
.
6. In the selection list
ADDRESSING
MODE
, select the setting
NAME
and confirm by pressing
CONNECT
.
The connection with the interrogator is established. The command strings can be trans-
ferred.
Note
For this purpose, select the setting C
OMMAND
on the register tab O
BJECT
T
RIGGER
C
ONTROL
as
Trigger source.