Chapter
8
Operating Instructions
Radio Frequency RFH620 Interrogator
58
©
SICK AG · Division Auto Ident · Germany · All rights reserved
8013105/0000/2009-05-12
Maintenance
8.4.2
Replacing the interrogator
1. Align and install the new or repaired interrogator (see
chapter 5 Installation, page 31
).
In the process, observe any marks made previously on the holder or the environment
(
chapter 8.4.1 Dismantling the interrogator, page 57
).
2. Re-connect connection cables to the interrogator (see
chapter 6 Electrical installation,
).
3. Switch the power supply to the interrogator back on.
The interrogator starts with the default setting.
4. If, as an option, a Micro SD memory card has been inserted into the interrogator or a
parameter memory module CMC600 into connection module CDB620/CDM420, the
new interrogator will automatically load the stored parameter set from the memory card
or CMC600 into its permanent memory. If both a memory card and a CMC600 are
available, the interrogator will load the parameter set from the CMC600.
- or -
Without Micro SD memory card /parameter memory module CMC600: Connect to the
interrogator via the SOPAS-ET configuration software, transfer the configuration stored
on the PC via download to the interrogator and permanently store the configuration the-
re.