Rated insulation voltage
At altitudes up to 2,000 m above sea level
230 V AC
At altitudes 2,000 m above sea level …
4,000 m above sea level
150 V AC
Overvoltage category
III
Contamination rating
2
Rated impulse withstand voltage U
imp
6 kV
1))
Time the enabling current paths of the safety relay remain open before closing again.
Table 14: Electrical data - enabling current path, release-delayed (37, 38)
Utilization category
DC-13 (0,1 Hz): 24 V, 2 A (IEC 60947-5-1)
Number of release-delayed enabling current
paths (normally open)
1
Switching voltage
10 V DC … 30 V DC
Switching current
2 mA … 2 A,
,
DC switching capacity
0.02 W … 70 W,
Switching frequency
≤ 1 Hz depending on the release delay
Contact fuse with safety fuse gG or circuit
breaker C
Max. 2 A
1))
Time the enabling current paths of the safety relay remain open before closing again.
Table 15: Ambient data
Enclosure rating
IP20 (IEC 60529)
Ambient operating temperature
At altitudes up to 2,000 m above sea level
(UL/CSA: surrounding air temperature)
–25 °C … +55 °C
At altitudes 2,000 m above sea level …
3,000 m above sea level
–25 °C to 50 °C
At altitudes 3,000 m above sea level …
4,000 m above sea level
–25 °C … +45 °C
Storage temperature
–25 °C … +70 °C
Permissible operating height
≤ 4,000 m
Air humidity
10% … 95%, non-condensing for climatic con‐
ditions according to IEC 61131-2
Emitted interference
In accordance with IEC 61000-6-4
Immunity to interference
In accordance with IEC 61326-3-1
In accordance with IEC 61000-6-2
In accordance with IEC 60947-5-1
11
TECHNICAL DATA
32
O P E R A T I N G I N S T R U C T I O N S | ReLy TIME1
8024303/2019-12-18 | SICK
Subject to change without notice