6.10
Other indicators and functions
Incorrect teach-in
SEN
TST
TCH
PWR
Q
In the event of a teach-in failure, Err appears on the display and the Q LED and TCH LED
flash.
Control panel locked
SEN
TST
TCH
PWR
Q
If the device is undergoing an internal process (e.g., reading or storing parameter sets
or teaching-in via IO-Link), the control panel is locked and the device shows “bSY” on
the segment display.
Short-circuit and overcurrent detection
SEN
TST
TCH
PWR
Q
In the event of a short-circuit and overcurrent, Err appears on the display and the Q LED
flashes.
Live measured value (run mode)
In run mode, the device displays the quality compared to the reference print in %.
The higher the value, the better the correspondence with the taught-in print.
SEN
TST
TCH
PWR
Q
6
OPERATION
26
O P E R A T I N G I N S T R U C T I O N S | PSS Prime
8022051/2018-01-31 | SICK
Subject to change without notice