5.2
Note on the swivel connector
NOTICE
Damage to the connector unit from over-tightening!
The connector unit on the device has two opposite end positions.
■
Do not rotate the connector unit from either of the two end positions by more than
180°.
5.3
Pin assignment of the connections
Pin assignment
PSS Print Detector
1
L+
2
ET
3
M
4
Q / C
5
Trigger
1
2
5
4
3
IO-Link
No.
Description
Data type
Bit 0
Switching signal Q
Boolean
Bit 1
Empty
-
Bit 2
Q valid
Boolean
Bit 3 - 7
Empty
-
Bit 8 - 15
Quality of print
Unsigned integer
5.4
Connecting the supply voltage
NOTICE
Risk of damage to the device!
The device can become damaged if it is connected to a voltage supply that is already
switched on.
•
Only connect the device when the supply cable is de-energized.
The device must be connected to a power supply unit with the following properties:
•
Supply voltage DC 10.8 V – 28.8 V (SELV/PELV as per currently valid standards)
•
Electricity source with at least 3 W power
To ensure protection against short-circuits/overload in the customer’s supply cables,
the wire cross-sections used must be appropriately selected and protected.
5
ELECTRICAL INSTALLATION
14
O P E R A T I N G I N S T R U C T I O N S | PSS Prime
8022051/2018-01-31 | SICK
Subject to change without notice