5
Electrical installation
5.1
Electrical installation
The sensors must be connected in a voltage-free state. The following information must
be observed, depending on the connection type:
Only apply voltage/switch on the voltage supply once all electrical connections have
been established.
Explanation of the connection terminology used in the following tables:
BN = brown
WH = white
BU = blue
BK = black
Q1 = switching output 1
L+ = supply voltage (U
B
)
M = ground
MF = (pin 2 configuration) = external input, teach-in, switching signal
Q
L1
/C = switching output, IO-Link communication
5.2
Pin assignment of the connections
U
B
: 10 ... 30 V DC
Table 5: Overview of pin assignment
-2X329x
-2X119x
C-2Xxx9xAxx
1
+(L+)
+(L+)
+(L+)
2
Q
Q
MF
3
-(M)
-(M)
-(M)
4
Q
Q
Q
1
/C
1
2
4
3
1 = BN
2 = WH
3 = BU
4 = BK
0.09 mm
2
AWG 28
1
2
4
3
1 = BN
2 = WH
3 = BU
4 = BK
0.09 mm
2
AWG 28
ELECTRICAL INSTALLATION
5
8021879.1CXK /2021-09-20 | SICK
O P E R A T I N G I N S T R U C T I O N S | PowerProx Micro - WTT2SL(C)
27
Subject to change without notice
en
Summary of Contents for PowerProx Micro WTT2SL Series
Page 81: ...PowerProx Micro WTT2SL C de en es fr it ja pl pt ru zh...
Page 87: ...2 5 2 6 BGV A3 2 8021879 1CXK 2021 09 20 SICK PowerProx Micro WTT2SL C 87 ja...
Page 89: ...4 2 95 4 3 L 37 38 4 8021879 1CXK 2021 09 20 SICK PowerProx Micro WTT2SL C 89 ja...
Page 128: ...PowerProx Micro WTT2SL C de en es fr it ja pl pt ru zh...
Page 134: ...SICK AG b b 2 5 2 6 2 134 PowerProx Micro WTT2SL C 8021879 1CXK 2021 09 20 SICK ru...
Page 135: ...BGV A3 2 7 2 8 SICK AG 2 8021879 1CXK 2021 09 20 SICK PowerProx Micro WTT2SL C 135 ru...
Page 144: ...PowerProx Micro WTT2SL C de en es fr it ja pl pt ru zh...
Page 150: ...BGV A3 2 7 2 8 SICK AG 2 150 PowerProx Micro WTT2SL C 8021879 1CXK 2021 09 20 SICK zh...