8013154/U275/2010/02/01
© SICK AG • Germany • All rights reserved • Subject to change without notice
33
Operating Instructions
PBS
Specifications
Model PBS
Long-term drift
% of span
≤
0.2
according to IEC 61298-2
Permissible temperature of
Medium
°C
-20 ... +85
Ambience
°C
-20 ... +80
Storage
°C
-20 ... +80
Rated temperature range
°C
0 ... +80
Temperature error within rated
temperture range
% of span
≤
1.0 typ.,
≤
2.5 max.
Temperature coefficients within rated
temperture range
Mean TC of zero
% of span
≤
0.2 / 10 K
Mean TC of span
% of span
≤
0.2 / 10 K
Reference condition
%
Relative humidity: 45 ... 75 according to IEC 61298-1
RoHS-conformity
Yes
CE-conformity
Pressure equipment directive
This instrument is a pressure accessory as defined by the directive
97/23/EC
EMC directive
2004/108/EEC, EN 61326-2-3
Shock resistance
g
50 according to IEC 60068-2-27
(mechanical shock)
Vibration resistance
g
10 according to IEC 60068-2-6
(vibration under resonance)
Wiring protection
Overvoltage protection
V DC
40
Short-circuit proofness
Q
A
/Q1/Q2 towards M
Reverse polarity protection
L+ towards M
Weight
kg
Approx. 0.2
7. Starting, operation
7. Starting, operation
GB
When designing your plant, take into account that the stated values (e.g.burst pressure, over
pressure safety) apply depending on the material, thread and sealing element used.