![SICK OD7000 Prime Operating Instructions Manual Download Page 42](http://html1.mh-extra.com/html/sick/od7000-prime/od7000-prime_operating-instructions-manual_1264021042.webp)
Example
Table 6: Example
Input
Comment
SODX
256
257
Selects distance 1 (=256) and intensity 1 (=257) included in the out‐
put.
SODX ?
Queries the currently active signal IDs.
Configuration with commands
Command
SODX
Complementary information
•
Protocol and command reference with information on the selection of the meas‐
ured values and the underlying signal IDs, available at
Further topics
•
7.3.14
Saving user-specific parameters
Important information
NOTICE
Loss of configuration data
Settings of the device are not saved automatically.
b
Save settings made manually.
Approach
b
Before ending the configuration, save changed settings in the non-volatile data
memory of the device.
✓
When restarting, the last saved settings are loaded.
Configuration with commands
Command:
SSU
(saving the configuration in the non-volatile data memory)
Example
Input
Action
SSU
Saves the current settings in the non-volatile data memory (no argu‐
ment supported).
7.3.15
Reset to factory settings
Configuration with commands
The command
SFD
resets all device parameters to the factory settings. The only excep‐
tion is network settings. If no argument or "0" is specified together with the command
SFD
, the network settings are not reset. Only command
SFD 1
also resets network
settings.
Example
Input
Action
SFD
Resets the parameters except for the network settings to the factory
settings.