4
Grounding point 3
5
Insulated mounting
6
Grounding point 2
7
Ground potential difference
8
Grounding point 1
9
Metal housing
ß
Shielded electrical cable
Even in the event of large differences in the ground potential, ground loops are effec‐
tively prevented. As a result, equalizing currents can no longer flow via the cable shields
and metal housing.
NOTICE
The voltage supply for the device and the connected peripheral devices must also
guarantee the required level of insulation.
Under certain circumstances, a tangible potential can develop between the insulated
metal housings and the local ground potential.
6.3
Connection diagram
NOTE
The recommended connecting cables and their associated technical data can be found
online at:
Interface A
Figure 10: Terminal strip, 9-pin
Contact Signal
Function
1
RS-232 TX/RS-422 TX-
Sender RS-232 / RS422 -
2
RS-232 RTS/RS-422 TX+
Sender RS-232 / RS422 +
3
RS-232 CTS/RS-422 RX-
Receiver RS-232 / RS422 -
4
RS-232 RX/RS-422 RX+
Receiver RS-232 / RS422 +
5
GND
Weight
6
SYNC-IN
Trigger input
7
SYNC-OUT
Trigger output
8
Spare
Spare
9
GND
Weight
ELECTRICAL INSTALLATION
6
8027188//2022-05-25 | SICK
O P E R A T I N G I N S T R U C T I O N S | OD7000
31