SP1
„0“
„0“
„1“
WR
Hyst.
Hyst.
Figure 10: Switching behavior in cylinder switch mode (default: top; inverted: bottom)
SP1
Switching point SP1
WR
Working range
Hyst.
Hysteresis
8.3.2.4
Window mode
For each switching point (SP1 and SP2), window mode defines a range within which the
switching output is switched to active.
The hysteresis is at the corresponding switching point in each case.
NOTE
Additional conditions:
•
SP1 + 1.5 mm + 1 * hysteresis < working range
•
SP1 - 1.5 mm - 1 * hysteresis > 0
SP2
SP1
„0“
„0“
„1“
WR
Hyst.
Hyst.
Figure 11: Switching behavior in window mode (default: top; inverted: bottom)
SP1
Switching point SP1
SP2
Switching point SP2
WR
Working range
Hyst.
Hysteresis
OPERATION
8
8019721.1FIH/2022-06-01 | SICK
O P E R A T I N G I N S T R U C T I O N S | MPS-C