8.4.2
Overview of teach-in modes
Analog outputs
LEDs
Teach-in mode
Hold
Define measuring range
(analog)
< 2 s
2 Hz
Set measuring range to the
maximum measuring range
for the length variant
> 2 s, < 5 s
4 Hz
2 Hz
Switch between current
and voltage output
> 5 s, < 8 s
2 Hz
4 Hz
Invert analog output
(0 V ...10 V -> 10 V ... 0 V) .
(
4 mA ... 20 mA -> 20 mA ... 4 mA
)
> 8 s, < 11 s
4 Hz
2 Hz
Teach in digital switching
output (see table below)
> 11 s, < 15 s, then lift
finger
= lights up,
= flashes,
= off
Digital output
LEDs
Teach-in mode
Hold
2 Hz
Single point (define switch‐
ing point)
< 3 s
2 Hz
2 Hz
Cylinder switch (define
measuring range around
individual measuring point)
> 3 s, < 6 s
2 Hz
2 Hz
Window (define measuring
range)
> 6 s, < 9 s
2 Hz
2 Hz
2 Hz
Reset BDC1 to default val‐
ues
> 9 s, < 12 s
4 Hz
2 Hz
Invert switching behavior
(HIGH -> LOW)
> 12 s, < 15 s
4 Hz
4 Hz
= lights up,
= flashes,
= off
OPERATION
8
8019721.1FIH/2022-06-01 | SICK
O P E R A T I N G I N S T R U C T I O N S | MPS-C
23
Subject to change without notice