An analog output changes its output current from 4 to 20 mA or from 20 to 4 mA analo‐
gously to the measured object.
All measuring functions are configured manually. The configurable details are shown for
the selected measuring function.
7.5.1
Object height measurement
An analog output changes its output current analogously to the height of an object.
Figure 89: Settings for object height measurement
b
Configure the alignment of the object in the detection area:
•
Height measurement starting at beam 1 (LBB)
The output provides a current which is analogous to the height of the highest
blocked beam.
•
Height measurement starting at the last beam (LBB)
The output provides a current which is analogous to the height of the lowest
blocked beam.
Output settings
For general options for analog outputs, see section
see "Advanced settings for the out‐
.
7.5.2
Hole detection
An analog output changes its output current analogously to the total number of beams
made.
Figure 90: Hole detection
The output current increases with the number of beams made.
CONFIGURATION WITH SOPAS ET
7
8017460.ZIK1/2017-02-13 | SICK
O P E R A T I N G I N S T R U C T I O N S | MLG-2 Pro
81
Subject to change without notice