7.14.1
Beam functions
Name
Function (English)
Function (German)
Description
NBB
Number of Beams
Blocked
Anzahl unterbroch‐
ener Strahlen
Total number of beams blocked (e.g.,
for object detection)
NBM
Number of Beams
Made
Anzahl freier Strah‐
len
Total number of beams made (e.g.,
for hole detection)
NCBB
Number of Consecu‐
tive Beams Blocked
Anzahl zusammen‐
hängender unter‐
brochener Strahlen
If there are multiple objects in the
detection area, the greatest number
of consecutive beams blocked is dis‐
played.
NCBM
Number of Consecu‐
tive Beams Made
Anzahl zusammen‐
hängender freier
Strahlen
If there are multiple gaps in the
detection area, the greatest number
of consecutive beams made is dis‐
played.
LBB
Last Beam Blocked
Letzter unterbroch‐
ener Strahl
Beam number of the last beam
blocked (e.g., for object height meas‐
urement)
LBM
Last Beam Made
Letzter freier Strahl
Beam number of the last beam
made
FBB
First Beam Blocked
Erster unterbroch‐
ener Strahl
Beam number of the first beam
blocked (e.g., for height classification
of a hanging object)
FBM
First Beam Made
Erster freier Strahl
Beam number of the first beam
made
ODI
Outside
Dimension
Außenmaß
Total number of beams between the
first and last beams blocked (e.g., for
measuring the outside dimension)
IDI
Inside
Dimension
Innenmaß
Total number of beams made
between the first and last beams
blocked (e.g., for measuring the
inside dimension)
CBB
Central Beam
Blocked
Zentraler unter‐
brochener Strahl
Beam number of the central beam
blocked (e.g., for measuring an
object position)
CBM
Central Beam Made Zentraler freier
Strahl
Beam number of the central beam
made (e.g., for measuring a hole
position)
BNB
Beam Number
Blocked
Strahlnummer x
unterbrochen
True when a predefined beam is
blocked
BNM
Beam Number Made Strahlnummer x frei True when a predefined beam is
made
ALARM Q1
–
–
Configuration same as with SOPAS
ET
QoR
Quality of Run
Process quality
0 … 100 percent
QoT
Quality of Teach
Teach-in quality
0 or 100 in percent
0 = teach-in was unsuccessful
100 = teach-in was successful
RLC1 … 16 Run-length code
–
Outputs the value of the relevant
change
NBB Zone X
(X = 1, 2, 3
or 4)
Number of Beams
Blocked Zone X
Number of Beams
Blocked Zone X
Total number of beams blocked (e.g.,
for object detection) in the indicated
zone
Table 33: Beam functions for preliminary evaluation
CONFIGURATION WITH SOPAS ET
7
8017460.ZIK1/2017-02-13 | SICK
O P E R A T I N G I N S T R U C T I O N S | MLG-2 Pro
107
Subject to change without notice