![SICK miniTwin2 Original Instructions Manual Download Page 44](http://html1.mh-extra.com/html/sick/minitwin2/minitwin2_original-instructions-manual_1264672044.webp)
Chapter
5
Operating Instructions
miniTwin2
44
© SICK AG • Industrial Safety Systems • Germany • All rights reserved
8013482/YT85/2016-02-23
Subject to change without notice
Electrical installation
5.1.1
Pin assignment system connection
Pin Wire colour
Meaning
Comment
1
Brown
24 V DC input
Voltage supply of the miniTwin2
2
White Multifunction
connection
Connection of the reset button
Or:
EDM connection
Or:
0 V DC (no function active)
3
Blue
0 V DC
Voltage supply of the miniTwin2
4
Black
OSSD
Output signal switching device
FE Grey
Functional earth
To ensure full electromagnetic compatibility
(EMC), functional earth (FE) must be
connected.
Pre-assembled cables with flying leads are available for the connection to your application
(see section 10.6 “Accessories” on page 77).
Fig. 34: Pin assignment
system connection
Tab. 6: Pin assignment
system connection
4
1
2
FE
3