Electrical installation
5.1
System connection
The miniTwin2 safety light curtain is connected using a system plug on the device
connection. For standalone devices a system plug with a system connection is available.
Never connect cables directly to the device connection!
You are only allowed to undertake the electrical installation of the miniTwin2 safety light
curtain with the aid of the pre-configured system plug (see Fig. 34 on page 44).
The system plug can also be fitted to the device connection rotated by 180°.
Connect the system plug to the device connection with the device electrically isolated.
Fasten the screws on the system plug to a maximum torque of 1 Nm.
Then connect the system connection to the connection for your application.
Fig. 32: Device connection
and system plug with system
connection
WARNING
Fig. 33: Mounting of the
system plug
System plug for
standalone
devices
System plug
rotated by 180°
Device connection
System connection