![SICK miniTwin2 Original Instructions Manual Download Page 19](http://html1.mh-extra.com/html/sick/minitwin2/minitwin2_original-instructions-manual_1264672019.webp)
Operating Instructions
Chapter
3
miniTwin2
8013482/YT85/2016-02-23
© SICK AG • Industrial Safety Systems • Germany • All rights reserved
19
Subject to change without notice
Product description
3.5.1
Reset
The dangerous state of the machine ( ) is interrupted if the light path is broken ( ), and
is not re-enabled ( ) until the operator presses the reset button.
Do not confuse reset and the restart interlock with the starting interlock on the machine.
The starting interlock prevents the machine starting after switching on. Reset and the
restart interlock prevent the machine starting again after an error or an interruption of the
light path.
You can only implement a restart interlock via an external machine restart interlock:
The miniTwin2 has no control over the restart.
You can implement a reset using the Reset function on the miniTwin2:
The miniTwin2 controls the machine start.
Ensure on the usage of the Reset function that an erroneous start-up cannot result in a
dangerous situation!
Fig. 9: Outline drawing of the
protective operation
Note
WARNING