O P E R AT I N G I N S T R U C T I O N S | L F P C U B I C
8019918/ZJA6 / 2017-07-20 | S I C K A G
Subject to change without notice
5 0
10
OVERVIEW OF PARAMETERS
Parameter
Description
Pulse
“8.4.5 Selection of evaluation method”.
AutCal
TrsHld
This value describes a factor which determines how strong
an echo has to be in order to be recognized by the device.
The value range lies between 20% and 500%. The default
is 100% in this case. Only shown if password entered.
•
20% = high sensitivity
•
100% = standard
•
500% = low sensitivity
AutoTn
“8.4.3 Automated adjustment of the interference
CalRng
Calibration range.
• Value range: 95 mm … 6005 mm
Range starting from the process connection in which
static interference signals (coupling sections, welds, spray
balls, etc.) are hidden during the AutCal process. During
the AutCal process, there must not be any medium in the
defined area of +200 mm.
“8.4.8 Teaching in static interference signals”
.
MaskZn
“8.4.4 Blanking the interference signals in the
MaskTr
“8.4.4 Blanking the interference signals in the
Reset
Resets the value for AutCal.
Foam
“7.3 Foam commissioning (with factory settings)”.
CalEmp
“7.3 Foam commissioning (with factory settings)”.
CalMed
“7.3 Foam commissioning (with factory settings)”.
Limit
Limit between foam and fluid.
•
Range: 20 to 100%
•
Factory setting: 90%
•
Medium surface: 90%
•
Foam surface: < 90%
When measuring the foam surface, it may be necessary to
reduce the limit. If the sensor displays a limit value that is
too low, it is necessary to reduce the limit.
Reset
Resets the values for CalEmp and CalMed.
Probe
Special settings.
Length
• See
“7.3 Foam commissioning (with factory settings)”
(LFP Cubic).
CblLen
“8.4.10 Changing the coaxial cable length”.
Type
Choosing between rod and rope.
Info
Sensor information.
FrmVer
Shows the firmware version.
SerNo
Shows the serial number.
CalSta
Displays the status of the tank calibration.
• Pulse = AutCal (calibrated), NoCal (not calibrated)
• Foam = FomCal (calibrated), CalMis (not calibrated)
AppTag
Measuring point name, can only be described via IO-Link.