O P E R AT I N G I N S T R U C T I O N S | L F P C U B I C
8019918/ZJA6 / 2017-07-20 | S I C K A G
Subject to change without notice
2 2
6
ELECTRICAL INSTALLATION
6.2
Electrical connection
6.2.1
Overview of the electrical connections
The sensor is connected using a pre-assembled female cable connector with
M12 x 1 plug connector (5/8-pin). With the power switched off, plug the female
cable connector into the sensor and screw it tight.
Connect the cable according to its function. After the supply voltage is set up, the
sensor performs a self-test. Once installed, the sensor is ready for operation upon
completion of the self-test (< 5 s). The display shows the current measured value.
Fig. 5: LFP Cubic
6.2.2
Pin assignment, M12 plug connector, 5-pin
1
2
4
3
5
Fig. 6: M12 x 1 plug connector, 5-pin
Contact
Marking
Wire color
Description
1
L+
Brown
Supply voltage
2
Q
A
White
Analog current/voltage output
3
M
Blue
Ground, reference potential for
current/voltage output
4
C/Q
1
Black
Switching output 1, PNP/ IO-Link
communication
5
Q
2
Gray
Switching output 2, PNP/ NPN