NOTE
Assign the functions for the digital inputs in the device using a configuration tool, e.g.
the configuration software SOPAS ET.
13.4.7
Wiring the digital outputs “Result 1” and “Result 2” of the device in the CDM420-0006
Device = Lector61x = V2D61xx- xxxxxEx
Device
1
CDM420-0006
Load (e.g. PLC)
4
C
5
.
.
.
E
Result
D
13
GND
5
Shield
+24 V* (V
S
)
V
S
GND
V
out
Result
A
GND
B
1
2
1
For inductive load:
6
5
2
3
3
1
7
2
6
5
4
8
13
14
17
15
9
10
12
16
11
8
7
1
10
15
6
11
5
Figure 44: Wiring the digital outputs “Result 1” and “Result 2” of the device in the connection module CDM420-0006
NOTE
The digital output “Result 3” of the device is not available in the CDM420-0006.
1
Device
2
Supply voltage V
S
3
Adapter cable (female connector, M12, 17-pin, A-coded/male connector, D-Sub-HD, 15-pin)
4
Load (e.g. PLC)
5
Output voltage V
out
6
With inductive load: see note
7
Connection module: female connector, D-Sub-HD, 15-pin
8
Connecting cable permanently connected with the device (male connector, M12, 17-pin, A-coded)
Inductive load
NOTE
Provide an arc-suppression switch at the digital output if inductive load is present.
b
Attach a freewheeling diode directly to the load for this purpose.
Table 34: Assignment of placeholders to the digital outputs
Device
CDM420-0006
Output A
Pin B
Pin C
Signal D
Terminal E
Result 1
13
12
Result 1
14
Result 2
14
13
Result 2
15
13
ANNEX
76
O P E R A T I N G I N S T R U C T I O N S | Lector61x
8024830/17IL/2020-04-02 | SICK