![SICK Lector61x Operating Instructions Manual Download Page 60](http://html.mh-extra.com/html/sick/lector61x/lector61x_operating-instructions-manual_1264267060.webp)
“V
S
”
“Host 2”
“Result 2”
“Result 3”
“Result 1”
“CAN”
“Sensor 2”
“Sensor 1”
“AUX”
CAN bus
“Result 1”
“Result 2”
PLC
“Result 3”
CDB650-204
Connection module
5
“Host 2”
HOST/PLC
Further data
processing
7
PC
Configuration
Diagnostics
Image display
Interfaces
3
Device
2
“Ethernet” (Host 1/Aux), Image transfer
4
RS-232
Ethernet
“Host 1”
Ethernet
“Aux”
“Sensor 2”
“Sensor 1”
1
V
S
8
9
6
Figure 29: Connection of the device to peripherals via CDB650-204 (overview)
1
External trigger sensor, e.g. for read cycle generation
2
Device
3
Interfaces
4
Image transmission
5
Connection modules
6
Configuration, diagnostics or image display
7
Data further processing
8
Supply voltage V
S
9
Application-dependent alternative stop trigger (e.g. photoelectric sensor) or travel increment (incremental encoder)
13.3.2
Wiring overview of the CDB650-204
Device = Lector61x = V2D61xx- xxxxxEx, 1 digital input used
13
ANNEX
60
O P E R A T I N G I N S T R U C T I O N S | Lector61x
8024830/17IL/2020-04-02 | SICK
Subject to change without notice