NOTE
The following functions are deactivated in
Live
mode:
•
Digital inputs and outputs
•
Data output via the host interface.
2.
Align the device in the desired depth of field range with a medium-height object
with a test code.
3.
Click the
Camera & Illumination
configuration bar. Use the
Shutter timer
and
Brightness
sliders to adjust the image brightness so that the code is easy to see.
4.
Only available in
Extended
mode: activate the sharpness diagnostic bar. To do this,
go to the
Camera & Illumination
area and click the
Display sharpness
checkbox.
Continuing configuration
1.
Make settings for additional functions during planned operation such as codes,
trigger, data processing, data interface, etc.
2.
In the
Online Images
window, click the
Operation
button and test the settings in oper‐
ational use.
Completing the configuration
1.
To permanently save the parameter set in the device: Click the
button.
2.
To permanently save the parameter set on the PC: Click the
button.
7.2
Configuring the device via the button without configuration software (SOPAS ET)
The function key and the LEDs in their third display level are used to manually configure
the device.
NOTICE
The
Tuning
function is not supported for OCR detection or pharmacodes.
1.
To start
Live
mode, press the function button (
p
) for 3 seconds.
Ready
5
0
7
0
1
2
0
2
0
0
3
0
0
Light
Test
Aiming
Focus
U-Def
L/A Eth
Tuning
Result
Ready
5
0
7
0
1
2
0
2
0
0
3
0
0
Light
Test
Aiming
Focus
U-Def
L/A Eth
Tuning
Result
Press function key 3 seconds
1
1
Press the function button (
p
) for 3 seconds.
✓
The device exits the current read mode and switches into button operation mode.
The device now ignores all further external read cycles. The device no longer out‐
puts any read results via the data interface.
✓
The device runs through all possible functions without executing them and then
starts again from the beginning. The LEDs light up one after the other for 1.5 sec‐
onds for each function in the third display level (functions:
Test
,
Aiming
,
Focus
,
Tun‐
ing
). The device cyclically repeats the process.
2.
To execute a function while the corresponding indication LED is lit, briefly press the
function button (
p
) once.
COMMISSIONING
7
8024830/17IL/2020-04-02 | SICK
O P E R A T I N G I N S T R U C T I O N S | Lector61x
43
Subject to change without notice