6.
Press the teach-in button. The switching threshold value appears.
OUT
7.5.1.3
Dynamic teach-in
1.
Press and hold Teach-in button for 2 s. Teach-in operating mode active.
2.
Use the plus or minus button to select dYn.
OUT
3.
Press the teach-in button to start.
OUT
4.
Let several objects pass.
5.
Press the teach-in button again to stop. The switching threshold value appears.
OUT
OUT
7.5.2
Adjusting switching threshold
During teach-in, the remission value of the switching threshold displayed is automati‐
cally set between the mark and background and corresponds to a switching threshold
of 50%. If the switching events do not correspond to the expected results, the switching
threshold can be adjusted independently of the teach-in process.
1.
Press the plus or minus button in Run mode. Switching threshold flashes.
OUT
2.
Adjust in single steps using the plus or minus button.
OUT
3.
Press Mode or wait 5 s to confirm.
7.5.3
Adjusting the switching logic (light/dark)
The “AUTO” switching logic is preset (factory setting). The first teach point is used as the
mark and the second as the background.
OPERATION
7
8023304.11XV/2018-11-29 | SICK
O P E R A T I N G I N S T R U C T I O N S | KTL180
25