3
Protective cover for bus female contact
4
End piece (accessory)
5
Bus male connector
1.
Mount the
2
base unit to the mounting rail.
2.
Mount the
4
end piece to the mounting rail directly behind the base unit to pre‐
vent slipping. (Optional)
3.
Close the female contact of the extension unit with protective cover.
3
.
4.
Mount the expansion unit
1
to the mounting rail.
5.
Push expansion unit to base unit
2
until the female contact of the basic unit and
bus male connector
5
of the expansion unit have a fixed contact.
4.5.1
Combination with other sensors
The KTL180 can be combined with other sensors on the same bus. The following table
lists other suitable products:
Product family
Sensor type
WLL180T
Fiber optic sensor
AOD1
Amplifier for OD1, OD5000, OL1 distance sensors
The following restrictions must be considered for the combination:
•
If KTL180 units are combined with WLL180T units, all WLL180T units used must
be mounted on the bus left of all used KTL180 units.
•
If KTL180 units are combined with AOD1 units, all KTL180 units used must be
mounted on the bus left of all used AOD1 units.
NOTE
If these combination orders are not followed, unspecific temporal behavior of the mea‐
sured value logging could occur.
NOTE
When combining sensors on the bus, there are additional restrictions concerning
usable functions,
see "Adjusting copy mode", page 32
.
4.6
Aligning fibers
ü
û
Figure 7: Align fibers with square light spot
With fibers with square light spots, the light spot must be aligned lengthwise to the
mark. Alignment does not play a role for fibers with round light spots.
4
MOUNTING
14
O P E R A T I N G I N S T R U C T I O N S | KTL180
8023304.11XV/2018-11-29 | SICK
Subject to change without notice