1
0
10
100
0
1,000
20
(0.79)
40
(1.57)
60
(2.36)
80
(3.15)
100
(3.94)
120
(4.72)
140
(5.51)
Operating reserve
Distance in mm (inch)
2
1
3
90 %/90 %
20 %/90 %
6 %/90 %
Image: H
2
Mount the sensor using a suitable mounting bracket (see the SICK range of acces‐
sories).
Note the sensor's maximum permissible tightening torque of 0.4 Nm.
3
The sensors must be connected in a voltage-free state (V
S
= 0 V). The information
in the graphics [B] must be observed, depending on the type of connection:
–
Male connector connection: pin assignment
–
Cable: core color
+ (L+)
not connected
-
(M)
brn
wht
blu
1
2
3
Q
blk
4
Image: B
GTE6-P/N4xxx, -P/N6xxx, -P/N7xxx
+ (L+)
-
(M)
Q
brn
blu
blk
Image: B-2
GTE6-P/N1xxx
Only apply voltage / switch on the power supply (V
S
> 0 V) once all electrical con‐
nections have been completed. The green LED indicator lights up on the sensor.
Explanations of the connection diagram (graphic B):
Switching output Q (according to graphic C):
GTE6-P (PNP: load -> M)
GTE6-N (NPN: load -> L+)
L = light switching
D = dark-switching
4
Align the sensor with the object. Select the position so that the red emitted light
beam hits the center of the object. You must ensure that the optical opening (front
screen) of the sensor is completely clear [E].
≈ 5 ... 7 °
Image: E
3
COMMISSIONING
2
8015312 | SICK
Subject to change without notice