7.7.2
Jump addresses
A jump address consists of a source jump address and a destination jump address.
The destination jump address assumes the same value (High or Low) as the associated
source jump address without any delay time whatsoever – unless it is a loopback. Infor‐
mation on loopbacks can be found in the “Flexi Soft in the Flexi Soft Designer”
(8012998) operating instructions.
Jump addresses are an elegant option for implementing complex logic relationships.
Among other things, jump addresses are used to connect the various pages of logic
with each other.
7.7.2.1
Finding source and destination jump addresses that belong together
To find the corresponding destination jump address for a source jump address (or vice
versa), proceed as follows:
1.
Right-click on the source or destination jump address.
2.
Click
Used on page
.
✓
A list of all pages containing elements of the jump address is displayed.
3.
Click on the desired page.
✓
The desired page is displayed. All elements of the jump address are highlighted in
color.
7.7.2.2
Adding a new source jump address
1.
Drag the
Add source jump address
symbol from the toolbar on the left of the logic cre‐
ation page into the working range.
2.
Enter a unique name in the
Create jump mark
dialog box.
3.
Click on
OK
.
7.7.2.3
Adding a new destination jump address
1.
Drag the
Add destination jump address
symbol from the toolbar on the left of the logic
creation page into the working range.
2.
Select the desired jump mark in the
Select jump mark
dialog box.
3.
Click on
OK
.
7.7.3
Verification of the logic
After the required parameters have been configured, the logic has to be certified before
being transferred to the safety controller.
The manufacturer of the machine is responsible for the output connections and for the
logic verification.
7.7.4
Transfer configuration
b
Transmit configuration to the Flexi Soft main module (see operating instructions
8012998).
7
CONFIGURATION
72
O P E R A T I N G I N S T R U C T I O N S | Safe Linear Positioning
8020941/12O9/2019-08-05 | SICK
Subject to change without notice