Table 13
Dataset type "Standard Volume Counters"
Unit
Description
Abbreviation
Metric
Imperial
Date/Time when data was saved
Date / Time
Sec
Sec
Flow Time
FlowTime
%
%
Total volume at flowing conditions (forward) Vo forward
m³
acf
Total volume at flowing conditions (reverse) Vo reverse
m³
acf
Volume at flowing conditions (forward)
Vf forward
m³
acf
Volume at flowing conditions (reverse)
Vf reverse
m³
acf
Error Volume at base conditions (forward)
Eb forward
Nm³
scf
Error Volume at base conditions (reverse)
Eb reverse
Nm³
scf
Volume at base conditions (forward)
Vb forward
Nm³
scf
Volume at base conditions (reverse)
Vb reverse
Nm³
scf
Averaged Performance
AvgPerformance
%
%
Pressure
Pressure
bar(a)
psi(a)
Temperature
Temperature
°C
°F
Compressibility
Compressibility
-
-
Meter Status (
DLOG Status
-
-
●
The dataset type "Standard Volume Counters" does not contain values for
"Averaged performance", "Pressure", "Temperature" or "Compressibility" for
gas velocities below the value for Vmin ("LowFlowCutOff", Reg. #7036).
●
The "Flow time" value shows, the percentage of storage cycle time the flow
was above Vmin and in the flow direction specified for the DataLog.
●
The values for all diagnostic information (see above) are flow-weighted.