Field setup
The MEPAFLOW600 CBM software "Field setup" wizard guides the user through the param-
eter configuration during the commissioning of the FLOWSIC600. The wizard consists of 8
pages. For checking the configuration of the SPU outputs refer to the "Instrument Data
Sheet" of the FLOWSIC600, which is included in the Manufacturer Data Record (MDR)
(example see
To start the Field setup, choose "Tools / Field Setup" from the menu.
Follow the instructions on screen step by step.
Figure 61
Example of an "Instrument Data Sheet" as contained in the MDR
The parameter changes performed in the Field setup wizard require the User
Access Level "Authorized operator" (see
0
1
54
2
56 *
Power supply / Power consumption
12 .. 28,8 V DC
< 1W
3
Type
57 *
Enclosure classification
4
Meter size
58 *
Cable entry
5 *
Article number
° 59
Hazardous Area Class.
6 *
TAG number
7 *
8 *
Order number
60
SPU housing material
9
° 61
Ambient temperature (range)
°C
10
Inner pipe diameter
mm
62
Display
11
Overal length (A)
mm
63
Display language
12
Overal height (B)
mm
64
Engineering units
13
Weight
kg
65
14
Flow range
m³/h
66
DO0/AO0 Terminals 31/32 (HF-Pulse)
15
Number of meas. paths
67
Signal configuration
16
Linearity
68
17 *
Repeatability
69
18
Flange design code
70
19
Flange class
71
20
Flange face
72
MOD Terminals 33/34 (RS 485)
21
Body material
73
DO1 Terminals 51/52 (HF-Pulse)
22
Transducers exchangeable under pressure
74
meter factor
1/m³
23 *
Transducer cover
75
Signal configuration
° 24
Design temperature
°C
76
max. Output
° 25
Design pressure
bar (g)
77
DO2 Terminals 41/42 (Status)
26
Material certificate
78
Signal configuration
27 *
Enclosure classification
79
max. Output
28 *
Surface coating / painting
80
DO3 Terminals 81/82 (RS 485)
29 *
Pressure tapping
81
30
82
31
83
32 *
Sensor material
84
Meter-No.: 3889
1/4" NPT female
Sensors
06'' / DN150
450,00
490,00
< 0,1%
Metric
8,2 V / 0,8...6,5 mA
8,2 V / 0,8...6,5 mA
No
Output and Signal Configuration - Signal processing unit
32 ... 2500
DIN/EN 1092-1
3.1 EN 10204
94
130
2.880
+/- 0.5% of MV 0.1 .. 1 Qmax
Form B2
1.0566 / ASTM A350 Gr. LF2
TRANSMITTER (Integral)
GENERAL
yp
Aluminium
SICK Modbus ASCII
Volume a.c.
NAMUR / normally open
Status Warning
2x RS 485
Titan 3.7165
Russian
147,00
LCD
FL600
-40 ... 60
IP 67
M20 x 1,5 (3x)
II 1/2G Eex de ib [ia] IIA T4
01/11-2
METER BODY
SICK Modbus ASCII
Volume a.c., no pulses when data invalid
NAMUR / normally open
NAMUR / normally open
-46 ... 100
4
Aluminium
PN100
IP 67
two layers: Epoxy + Acrylic RAL9002
COMMUNICATION
Interface