Assembly and installation
FLOWSIC200 · Operating Instructions · 8013271/1CJ9/V2-0/2022-01 · © SICK Engineering GmbH
41
3.2.6
Installing the MCU control unit
The control unit must be mounted on a vertical, level base at an easily accessible, well
protected location as shown in
.
Fig. 25
MCU installation dimensions in wall housing
The respectively suitable mounting kits can be used for fastening (
).
210
> 350
120
> 25
0
34
0
32
0
M8
Clearance for cables
160
Clearance for door swing area,
minimum sideways distance to passing
vehicles when fitted on the tunnel wall
When using suitable cables (
) , the control unit can be positioned
up to 1000 m away from the sender/receiver units (use bus wiring
according to p. 48, Fig. 29; length is overall length of all cables used).
We recommend installing the MCU in a control room or similar for trouble-
free communication with the FLOWSIC200.