17
8026957/AE00/V1-0/2021-08| SICK
O P E R A T I N G I N S T R U C T I O N S | DUSTHUNTER SB30
Subject to change without notice
PRODUCT DESCRIPTION
2
Sender/receiver unit interfaces
The following interfaces are available directly on the sender/receiver unit.
2.2.2
Flange with tube
The flange with tube is available in different steel grades and dimensions (
). Selection depends on the wall and isolation thickness of the duct wall
(
nominal length) and the duct material.
Fig. 7: Flange with tube
Analog output (1x)
0/2/4 ... 20 mA
Relay outputs
Load 48 V, 1 A
Digital input
Service / MCU
interface
For output of
measurand dust
concentration
For output of status
signals:
●
Operation/failure
●
Limit value
●
Warning/mainte-
nance/function
check (selectable)
E.g. for selection of
maintenance, function
check, linearity check,
calibration curve
switching, filter
monitoring synchronous
signal
For configuration with
SOPAS-ET or
connecting a MCU
NOTE:
A weather hood is mandatory when used outdoors. This prevents rainwater
from being sucked in (
TOP
NL
Marking for assembly position
Securing bolt
Material St 37 or 1.4571