Menu Structure
Profile
Encoder
This profile corresponds to the standard encoder profile,
for description, see section 13.2 "PROFIBUS Interface".
SICK (default)
This profile is based on the standard encoder profile. In
addition to the measured value, warning, condition and
error information are transmitted.
For description, see section 13.2 "PROFIBUS Interface".
Bus Address
Addr. 006 (default)
Set PROFIBUS address
(001 … 125)
Commissioning example with Siemens Step 7 see chapter 13 "Annex".
Hiperface
BusAddress
Add 00 (default)
Setting of the Hiperface address (area 0 … 31)
Baud rate
0.6 kBd
Baud rate setting
1.2 kBd
2.4 kBd
4.8 kBd
9.6 kBd (default)
19.2 kBd
38.4 kBd
Data
8, o, 1
8-data bit, odd parity, 1 stop bit
8, e, 1 (default)
8-data bit, even parity, 1 stop bit
8, o, 1
8-data bit, no parity, 1 stop bit
Timeout
X1
1*11/baud rate
X4 (default)
4*11/baud rate
Monitor
On
Serial monitor interface in operation, multifunctional
outputs MF1 and MF2 not in operation. Enables
parameterization of the DME5000 with the interface
adapter (see section 13.4 "Interface Adapter") or
monitoring of measured values via MF1 and MF2.
Off (default)
Multifunctional outputs MF1 and MF2 in operation as set
in item 3.3/3.4.