E.g., wire cross-section 0.34 mm²,
copper cable
15 m
E.g., wire cross-section 0.5 mm²,
copper cable
30 m
Ambient operating temperature
2)
3)
–30 °C … +55 °C
Air humidity (non-condensing)
15 % … 95 %
Storage temperature
–30 °C … +70 °C
Housing cross-section
31 mm × 34 mm, plus bracket,
Weight
Dependent on the number of beams,
Vibration resistance
4)
5 g, 10 Hz … 55 Hz (IEC 60068-2-6)
Shock resistance
5)
10 g, 16 ms (IEC 60068-2-27)
1)
Maximum permissible conductor resistances must be observed.
2)
The temperature difference between sender and receiver must not exceed 25 K.
3)
The cable belonging to the device incl. the associated connection plug must not be flexibly mounted
under -25°C.
4)
Test conditions per axis: 1 octave/minute, amplitude: 0.35 mm, 20 sweeps.
5)
Test conditions per axis: 1,000 shocks.
12.2
Table of weights
Table 13: Weight of sender and receiver
Number of beams
Weight in g
1)
s
Sender
r
Receiver
2
560
560
3
800
800
4
880
880
1)
Tolerance: ± 50 g
TECHNICAL DATA
12
8020453/14Q7/2020-04-27 | SICK
O P E R A T I N G I N S T R U C T I O N S | deTem4 Core
55