![SICK deTem4 Core Ex Operating Instructions Manual Download Page 25](http://html1.mh-extra.com/html/sick/detem4-core-ex/detem4-core-ex_operating-instructions-manual_1264385025.webp)
Important information
DANGER
Hazard due to unexpected starting of the machine
b
Make sure that the dangerous state of the machine is and remains switched off
during the check.
b
Make sure that the outputs of the multiple light beam safety device do not affect
the machine during the check.
DANGER
Hazard due to lack of effectiveness of the protective device
Persons and parts of the body to be protected may not be recognized in case of non-
observance.
Do not operate the machine if the OSSD LED lights up green during the test!
b
If the OSSD LED lights up green during the test, even if only briefly, work must stop
at the machine.
b
In this case, the mounting and electrical installation of the multiple light beam
safety device must be checked by appropriately qualified safety personnel.
Prerequisites
•
The OSSD LED lights up green.
Approach
1.
Cover a light beam completely.
r
✓
The OSSD LED on the receiver lights up red.
2.
Enable the light beam.
PROJECT PLANNING
4
8020453/14Q7/2020-04-27 | SICK
O P E R A T I N G I N S T R U C T I O N S | deTem4 Core
25
Subject to change without notice