Further topics
•
"Ordering information", page 57
5.3
Mounting
Important information
DANGER
Hazard due to lack of effectiveness of the protective device
Persons or parts of the body to be protected may not be recognized or not recognized in
time in case of non-observance.
b
Take into consideration the minimum distances calculated for the machine.
b
Mount multiple light beam safety devices such that nobody can pass under the
lowest light beam, pass over the highest light beam, get between two light beams,
or pass by the side of the protective device.
DANGER
Hazard due to lack of effectiveness of the protective device
Persons and parts of the body to be protected may not be recognized in case of non-
observance.
b
The end with the cable connection must point in the same direction for the sender
and receiver.
180˚
r
s
r
s
Figure 15: Sender and receiver must not be installed such that they are rotated 180° relative to
each other
Notes on mounting
b
Mount the sender and receiver on a level surface (
!
).
5
MOUNTING
28
O P E R A T I N G I N S T R U C T I O N S | deTem4 Core