8015589/ZNI9/2017-06-13 • Subject to errors and modifications • ©
SICK AG
•
Waldkirch
•
Germany
•
www.sick.com
CLV61x | SICK
3
Legend:
1
2 x threaded mounting hole M5, 5 mm deep for mounting the
CLV61x
2
Internal impact point: rotation point of the variable direction laser
beam
3
Central position of the deflected laser beam in the V-shaped aper
-
ture angle
4
Cable outlet, standard cable 0.9 m/2.95 ft (+10%) with 15-pin D-
Sub-HD plug
5
Reading window
6
Status display (1 x RGB-LED) with signal color allocation
7
Reference point for reading distance (housing edge) from CLV61x to
object
Optical Status Indicators
Ready
G Read
N Read
HW Err
UserDef1
LED
Signal
colors
Indicator colors and behavior of LED status display
Indicator
Color of LED
Status
Ready
O
Blue
Lights up constantly after switching on
and completion of successful self-test.
–
–
Goes out when downloading configu
-
ration data from the CLV61x
G Read
O
Green
Lights up briefly after Good Read
N Read
O
Red
Lights up briefly after No Read
HW Err
O
Red
Lights up constantly in case of
hardware error
Further
indicators
Red
Blue
Firmware download:
Indicator flashes alternately
O
Red
Firmware download:
Lights up constantly in case of error
O
= li
ghts up constantly or once briefly
= flashes,
= flashes alternately
Parameter
Value
Host interface
57.6 kBd, 8, n, 1,
Output format: 1
AUX interface
Output format: read diagnosis
Switching outputs
Result 1: Device Ready
Result 2: Good Read
Password protection for
parameters
No
Step 4: Fine Adjustment
1. Align the CLV61x so that the angle between the scanning
line and the bar code stripes is almost 90°.
2. Manually guide objects with bar codes successively into
the reading field of the CLV61x in a realistic manner and
check the reading result. If objects are only guided in an
unstructured manner, it may be necessary to check several
different positions of the bar codes. Here, it must be
ensured that the limit values of the permitted read angles
are not exceeded.
3. Adjust the CLV61x so that the good read rate is 100%.
Description of the Device
Device overview CLV61x
Reading window on front
0.
2
(0.01)
0.
2
(0.01)
38.
5
(1.52)
50°
61
(2.4)
All length measures in mm (inch)
Ready
G Read
N Read
HW Err
UserDef1
13.7
(0.54)
19.5
(0.77)
37.9
(1.94)
19.5
(0.77)
6.2
(0.24)
65.9
(2.59)
41.8
(1.65)
17.1
(0.67)
38.
5
(1.52)
(27.4)
(1
)
35.6
(1.4)
(25.4)
(1)
22.5
(0.89)
10
(0.39)
5.
7
(0.22)
Reading window on side
105°
50°
All length measures in mm (inch)
Ready
G Read
N Read
HW Err
UserDef1
22.5
(0.89)
5.
7
(0.22)
10
(0.39)
59.4
(2.34)
2
(.08)
14.9
(0.59)
10
(0.39)
60.4
(2.38)
35.6
(1.4)
23.8
(0.94)
16.4
(0.64)
60.5
(2.38)
2.
7
(0.11)
27.
4
(1.08
)
37.9
(1.49)
38.
5
(1.52)
22.5
(0.89)
5.
7
(0.22)
10
(0.39)
65.9
(2.59)
0.
2
(0.01)
0.
2
(0.01)
79.9
(3.14)