background image

8015589/ZNI9/2017-06-13 • Subject to errors and modifications • © 

SICK AG

 • 

Waldkirch

 • 

Germany

 • 

www.sick.com

CLV61x | SICK

3

Legend:

1

  2 x threaded mounting hole M5, 5 mm deep for mounting the 

CLV61x

2

  Internal impact point: rotation point of the variable direction laser 

beam

3

  Central position of the deflected laser beam in the V-shaped aper

-

ture angle

4

  Cable outlet, standard cable 0.9 m/2.95 ft (+10%) with 15-pin D-

Sub-HD plug

5

  Reading window

6

  Status display (1 x RGB-LED) with signal color allocation

7

  Reference point for reading distance (housing edge) from CLV61x to 

object 

Optical Status Indicators

 

Ready
G Read
N Read
HW Err
UserDef1

LED

 

Signal

colors

Indicator colors and behavior of LED status display

Indicator

Color of LED

Status

Ready

O

Blue

Lights up constantly after switching on 

and completion of successful self-test. 

Goes out when downloading configu

-

ration data from the CLV61x

G Read

O

Green

Lights up briefly after Good Read

N Read

O

Red

Lights up briefly after No Read

HW Err

O

Red

Lights up constantly in case of 

hardware error

Further 

indicators

 

Red 

Blue

Firmware download: 

Indicator flashes alternately

O

Red

Firmware download: 

Lights up constantly in case of error

O

 = li

ghts up constantly or once briefly 

 

 = flashes, 

 

 = flashes alternately

Parameter

Value

Host interface

57.6 kBd, 8, n, 1, 

Output format: 1

AUX interface

Output format: read diagnosis

Switching outputs

Result 1: Device Ready 

Result 2: Good Read

Password protection for 

parameters

No

Step 4: Fine Adjustment

1.  Align the CLV61x so that the angle between the scanning 

line and the bar code stripes is almost 90°. 

2.  Manually guide objects with bar codes successively into 

the reading field of the CLV61x in a realistic manner and 

check the reading result. If objects are only guided in an 
unstructured manner, it may be necessary to check several 
different positions of the bar codes. Here, it must be 
ensured that the limit values of the permitted read angles 
are not exceeded.

3.  Adjust the CLV61x so that the good read rate is 100%.

Description of the Device

Device overview CLV61x

Reading window on front

0.

2

(0.01)

0.

2

(0.01)

38.

5

(1.52)

50°

61 

(2.4)

All length measures in mm (inch)

 

Ready
G Read
N Read
HW Err
UserDef1

 

13.7 

(0.54)

19.5 

(0.77)

37.9 

(1.94)

19.5

(0.77)

6.2

(0.24)

65.9 

(2.59)

41.8 

(1.65)

17.1 

(0.67)

38.

5

(1.52)

(27.4)

(1

)

35.6

(1.4)

(25.4)

(1)

22.5

(0.89)

10 

(0.39)

5.

7

(0.22)

Reading window on side

105°

50°

All length measures in mm (inch)

 

Ready
G Read
N Read
HW Err
UserDef1

 

22.5 

(0.89)

5.

7

(0.22)

10

(0.39)

59.4 

(2.34)

2

(.08)

14.9

(0.59)

10

(0.39)

60.4 

(2.38)

35.6 

(1.4)

23.8

(0.94)

16.4 

(0.64)

60.5 

(2.38)

2.

7

(0.11)

27.

4

(1.08

)

37.9 

(1.49)

38.

5

(1.52)

22.5 

(0.89)

5.

7

(0.22)

10

(0.39)

65.9 

(2.59)

0.

2

(0.01)

0.

2

(0.01)

79.9 

(3.14)

Summary of Contents for CLV610-C0000

Page 1: ...ion about configuration can be found in the online help function of the configuration software SOPAS ET The information can be accessed as a PDF on the CLV61x product site on the web www sick com CLV61x Safety Information This chapter is about the safety of commissioning person nel as well as operators of the system in which the CLV61x is integrated Read these operating instructions before startin...

Page 2: ... as a stand alone device 4 Switch on the supply voltage for the CDB620 and the PC All LEDs on the CDB620 will light up briefly The CLV61x starts with a delay and uses the default parameters set in the factory for the initialization After a successful self test the LED on the CLV61x lights up blue to indicate the Device Ready status Step 3 Configuration with PC User Modes and Statuses of the CLV61x...

Page 3: ...briefly flashes flashes alternately Parameter Value Host interface 57 6 kBd 8 n 1 Output format 1 AUX interface Output format read diagnosis Switching outputs Result 1 Device Ready Result 2 Good Read Password protection for parameters No Step 4 Fine Adjustment 1 Align the CLV61x so that the angle between the scanning line and the bar code stripes is almost 90 2 Manually guide objects with bar code...

Page 4: ...FIELDBUS Configuration Diagnosis SOPAS SOPAS AUX RS 232 CAN DC 10 30 V PLC PC Further data processing e g cable no 6036106 2 m 6 56 ft DC 10 30 V AUX USB Reading result CLV61 FIELDBUS CAN Sensor Network PROFIBUS PROFIBUS CDF600 21xx PROFIBUS Fieldbus module Input 1 e g external reading clock Overview of pin assignment 15 pin D Sub HD plug CLV61x ECO N C N C N C TxD RS 232 HOST DC 10 30 V TxD RS 23...

Page 5: ...class III VDE 016 IEC 10110 1 Enclosure rating IP 65 DIN 40 050 EMC Radiated emission EN 61000 6 4 2007 01 A1 2011 Electromagnetic immunity EN 61000 6 2 2005 08 Vibration resistance Shock resistance EN 60068 2 6 2008 02 EN 60068 2 27 2009 05 Ambient tempera ture Operation 0 C 40 C Storage 20 C 70 C Permissible relative air humidity 90 non condensing 1 With switching outputs without load 2 Without ...

Page 6: ...ing window This effect can be avoided by using the SICK anti static plastic cleaner no 5600006 in combination with the SICK lens cloth no 4003353 Transport and Storage The CLV61x must be transported and stored in its original packaging The device must not be stored in airtight contain ers so that any residual moisture is able to escape Storage conditions dry dust free no direct sunlight 20 C 70 C ...