background image

8015589/ZNI9/2017-06-13 • Subject to errors and modifications • © 

SICK AG

 • 

Waldkirch

 • 

Germany

 • 

www.sick.com

CLV61x | SICK

4

Overview of all interfaces and connection options for CLV61x ECO/CAN

Input 2

(e.g. incremental encoder, 

Teach-in matchcode)

Input 1

(e.g. external reading clock)

Output 1

(e.g. indicator lamp)

Output 2

(e.g. indicator lamp)

CLV61x ECO/CAN

CDB620

Connection module 

Serial

Serial

Configuration

Diagnosis

SOPAS

SOPAS

Serial

Serial

“HOST (RS-232)/

AUX (RS-232)/

I/O”

...

...

1 2

DC 10 ... 30 V

GND

HOST

PC

Further data

processing  

e.g. cable no. 2014054 (2 m/6.56 ft)

“AUX” (RS-232)

DC 10 ... 30 V

Switching inputs/outputs = digital

“HOST” (RS-232)

Reading result

“CAN” (CLV61x CAN only) 

CAN Sensor Network

Overview of all interfaces and connection options for CLV61x FIELDBUS

Configuration

Diagnosis

SOPAS

SOPAS

“AUX (RS-232)/

CAN/DC 10...30 V”

PLC

PC

Further data

processing

e.g. cable 

no. 6036106 

(2 m/6.56 ft)

DC 10 ... 30 V

“AUX” (USB)

Reading result 

CLV61 FIELDBUS

CAN Sensor Network

PROFIBUS

PROFIBUS

CDF600-21xx

PROFIBUS

Fieldbus module

Input 1

(e.g. external reading clock)

Overview of pin assignment

15-pin D-Sub HD plug

CLV61x ECO

N.C.

N.C.

N.C.

TxD (RS-232), HOST

DC 10 ... 30 V

TxD (RS-232), AUX

RxD (RS-232), AUX

N.C.

GND

RxD (RS-232), HOST

Result 1 (switching output)

Result 2 (switching output)

7

6

Sensor 2 (switching input)

Sensor 1 (switching input)

SensGND

4

3

2

1

5

8

9

10

11

12

13

14

15

6 1

10

5

11

15

15-pin D-Sub HD plug

CLV61x CAN / FIELDBUS

CAN_L

CAN_H

N.C.

TxD (RS-232), HOST

DC 10 ... 30 V

TxD (RS-232), AUX

RxD (RS-232), AUX

N.C.

GND

RxD (RS-232), HOST

Result 1 (switching output)

Result 2 (switching output)

7

6

Sensor 2 (switching input)

Sensor 1 (switching input)

SensGND

4

3

2

1

5

8

9

10

11

12

13

14

15

6 1

10

5

11

15

N.C. = not connected

Summary of Contents for CLV610-C0000

Page 1: ...ion about configuration can be found in the online help function of the configuration software SOPAS ET The information can be accessed as a PDF on the CLV61x product site on the web www sick com CLV61x Safety Information This chapter is about the safety of commissioning person nel as well as operators of the system in which the CLV61x is integrated Read these operating instructions before startin...

Page 2: ... as a stand alone device 4 Switch on the supply voltage for the CDB620 and the PC All LEDs on the CDB620 will light up briefly The CLV61x starts with a delay and uses the default parameters set in the factory for the initialization After a successful self test the LED on the CLV61x lights up blue to indicate the Device Ready status Step 3 Configuration with PC User Modes and Statuses of the CLV61x...

Page 3: ...briefly flashes flashes alternately Parameter Value Host interface 57 6 kBd 8 n 1 Output format 1 AUX interface Output format read diagnosis Switching outputs Result 1 Device Ready Result 2 Good Read Password protection for parameters No Step 4 Fine Adjustment 1 Align the CLV61x so that the angle between the scanning line and the bar code stripes is almost 90 2 Manually guide objects with bar code...

Page 4: ...FIELDBUS Configuration Diagnosis SOPAS SOPAS AUX RS 232 CAN DC 10 30 V PLC PC Further data processing e g cable no 6036106 2 m 6 56 ft DC 10 30 V AUX USB Reading result CLV61 FIELDBUS CAN Sensor Network PROFIBUS PROFIBUS CDF600 21xx PROFIBUS Fieldbus module Input 1 e g external reading clock Overview of pin assignment 15 pin D Sub HD plug CLV61x ECO N C N C N C TxD RS 232 HOST DC 10 30 V TxD RS 23...

Page 5: ...class III VDE 016 IEC 10110 1 Enclosure rating IP 65 DIN 40 050 EMC Radiated emission EN 61000 6 4 2007 01 A1 2011 Electromagnetic immunity EN 61000 6 2 2005 08 Vibration resistance Shock resistance EN 60068 2 6 2008 02 EN 60068 2 27 2009 05 Ambient tempera ture Operation 0 C 40 C Storage 20 C 70 C Permissible relative air humidity 90 non condensing 1 With switching outputs without load 2 Without ...

Page 6: ...ing window This effect can be avoided by using the SICK anti static plastic cleaner no 5600006 in combination with the SICK lens cloth no 4003353 Transport and Storage The CLV61x must be transported and stored in its original packaging The device must not be stored in airtight contain ers so that any residual moisture is able to escape Storage conditions dry dust free no direct sunlight 20 C 70 C ...

Reviews: