1

CLV61x

Intended Use

The CLV61x bar code scanner is an intelligent SICK 4Dpro 
 sensor and is used exclusively for automatic, stationary iden-

tification and decoding of bar codes on moving or stationary 

objects. The data content of the decoded bar codes is sent  
by the CLV61x to a superordinate computer for further pro-
cessing. Depending on the model, this is either done directly 
via a serial data interface (RS-232) or indirectly via the  
SICK CAN sensor network on a coordinating device (e.g., 
master).  
Correct use also includes compliance with all information in 
these operating instructions as well as in the supplemen-
tary 

&

 

“CLV61x Bar Code Scanner” Technical Information 

 

(no. 8015592). 
The product family CLV61x consists of the three series ECO, 
CAN, and FIELDBUS (FIELDBUS in combination with the 

optional CDF600-21xx fieldbus module). Depending on the 

model, the series offer the following options:
•  Reading range variants (e.g., Short Range, Long Range)
•  Line scanner or raster scanner
•  Reading window on front or side
•  Different connecting cable lengths

All devices have two serial data interfaces (HOST/AUX). The 
CAN and FIELDBUS series also offer the SMART decoder for 

identifying partly damaged or low-quality bar codes as well as 
an additional CAN interface. 

About This Document 

The purpose of these operating instructions is to allow you 
to put the CLV61x into operation quickly and easily and to 
achieve initial read results as a stand-alone device.
The operating instructions describe the commissioning pro-
cess for an application with a 

single

 CLV61x. This is done, for 

example, using the device version CLV610-C0000 from the 
CAN series and its default setting. The CDB620 connection 
module, for example, is used for the industrial-standard signal 
distribution of the CLV61x. 
The operating instructions are valid for the following variants:
•  CLV610-C0000 (CAN, Mid Range, line scanner, reading 

window on front, SMART decoder)

•  CLV615-F2000 (FIELDBUS, Long Range, line scanner, 

reading window on side, CAN, SMART decoder)

In the following, the bar code scanner CLV61x is referred to in 

simplified form as “CLV61x.”

Supplementary Documents

More detailed information about mounting and electrical in-
stallation as a stand-alone device is available in 

&

 

“CLV61x 

Bar Code Scanner” Technical Information

 (no. 8015592). 

This document describes:
•  Optional mounting accessories (brackets)
•  The prevention of ground potential equalization currents in 

applications with widely distributed systems

•  Pin and lead color assignments of cables 
•  Electrical wiring plans for the CDB620 connection module 

relating to the CLV61x

Operation of the CLV61x CAN in the SICK CAN Sensor 
Network

The setup and wiring of the SICK-specific CAN network as well 

as the integration of the CLV61x

 CAN

 and 

FIELDBUS

 series in 

the network is described in the 

&

 

SICK CAN Sensor Network 

Operating Instructions

.

Operation of the CLV61x FIELDBUS in PROFIBUS DP

The integration of the CLV61x 

FIELDBUS

 series in PROFI-

BUS DP via the CDF600-21xx fieldbus module is described 

in the 

&

 “

CDF600-21xx Fieldbus Module PROFIBUS DP” 

Operating Instructions

 (no. 8015335) and the supplementary 

&

 “

CDF600-21xx Fieldbus Module PROFIBUS DP” Technical 

Information 

(no. 8015337).

Information about configuration can be found in the online 
help function of the configuration software SOPAS ET. 

The information can be accessed as a PDF on the CLV61x 
product site on the web 

(www.sick.com/CLV61x). 

 

Safety Information

•  This chapter is about the safety of commissioning person-

nel, as well as operators of the system in which the CLV61x 
is integrated. 

•  Read these operating instructions before starting any work 

on the CLV61x in order to familiarize yourself with the 
device and its functions. The operating instructions are 
considered a part of the device and must be kept in an 
accessible location in the immediate vicinity of the CLV61x 
at all times!

•  The CLV61x corresponds to laser class 2.  

Laser warning notice 

 see 

“Optical radiation: Laser class 

2 Page 6”

.

•  Opening the screws of the CLV61x housing will invalidate 

any warranty claims against SICK AG. For further warranty 
provisions, see the General Terms and Conditions of SICK 
AG, e.g., on the delivery note of the CLV61x.

Commissioning and Configuration

Scope of Delivery

•  CLV61x in the ordered version (series, reading range, scan-

ning method, reading window orientation)

•  Accessories that can be optionally ordered such as e.g. 

brackets

Step 1: Mounting

NOTE

Radio interference may occur when the CLV61x is used in 
residential areas!

 

>

The CLV61x must be used exclusively in industrial environ-
ments (EN 61000-6-4).

Equipment Required

•  2 x M5 screws for mounting the CLV61x on a mounting de-

vice (bracket). Screw length is dependent on the mounting 
base (wall thickness of bracket). When using optional SICK 
brackets, screws for the CLV61x are included.

Mounting Requirements

•  The permitted ambient conditions for the operation of the 

CLV61x must be complied with (e.g., temperature, radi-
ated emission, ground potential 

 see section  

“Technical 

Specifications (Excerpt) Page 5” and 

section 

“Risk of 

injury/risk of damage via electrical current! Page 2”

).

•  The device must only be mounted using the pairs of 

threaded mounting holes provided for this purpose. 

• 

Stable mounting device with sufficient load-bearing capac

-

ity and suitable dimensions for the CLV61x. 
Weight depends on model, max. 206 g (not including 
cables). For dimension drawing, 

 

see section 

“Device 

overview CLV61x” on page 3

•  Shock and vibration-free mounting.
•  Clear view of the bar codes to be measured on the objects. 

Mounting CLV61x

1.  Select a suitable mounting location for the CLV61x with a 

clear view of the object to be scanned. The mounting loca-
tion and position depend on the respective reading range 
of the CLV61x version. The available reading range is 
dependent on the distance from the code and the required 
resolution. The mounting location must therefore be cho-

sen whilst taking into account the respective reading field 

length and height, as well as resolution and depth of focus 
(

 see section 

“Reading fields Page 5”)

.

2.  Mount the CLV61x on a bracket using both screws. 

Mounting example: use of quick-clamping device (clamp bracket) 

no. 2025526 in combination with the mounting bracket no. 2020410

3.  Depending on the scanning method, roughly align the 

CLV61x on the object with the bar code to be measured.

Line scanner

Raster scanner

Allocation of scanning method to bar code and conveyor direction

β

α

γ

Depth of 

field 

Reading

distance

Possible read angle that could occur between scanning line and bar code

Angle

Limit Value

Tilt 

a

max. 30°

*)

Pitch 

b

max. 45°

Skew 

g

max. 45°

*)  depending on the module width

Bar Code Scanner

CLV610-C0000 CAN Mid Range

CLV615-F2000 FIELDBUS Long Range

OPERATING INSTRUCTIONS

en

Summary of Contents for CLV610-C0000

Page 1: ...ion about configuration can be found in the online help function of the configuration software SOPAS ET The information can be accessed as a PDF on the CLV61x product site on the web www sick com CLV61x Safety Information This chapter is about the safety of commissioning person nel as well as operators of the system in which the CLV61x is integrated Read these operating instructions before startin...

Page 2: ... as a stand alone device 4 Switch on the supply voltage for the CDB620 and the PC All LEDs on the CDB620 will light up briefly The CLV61x starts with a delay and uses the default parameters set in the factory for the initialization After a successful self test the LED on the CLV61x lights up blue to indicate the Device Ready status Step 3 Configuration with PC User Modes and Statuses of the CLV61x...

Page 3: ...briefly flashes flashes alternately Parameter Value Host interface 57 6 kBd 8 n 1 Output format 1 AUX interface Output format read diagnosis Switching outputs Result 1 Device Ready Result 2 Good Read Password protection for parameters No Step 4 Fine Adjustment 1 Align the CLV61x so that the angle between the scanning line and the bar code stripes is almost 90 2 Manually guide objects with bar code...

Page 4: ...FIELDBUS Configuration Diagnosis SOPAS SOPAS AUX RS 232 CAN DC 10 30 V PLC PC Further data processing e g cable no 6036106 2 m 6 56 ft DC 10 30 V AUX USB Reading result CLV61 FIELDBUS CAN Sensor Network PROFIBUS PROFIBUS CDF600 21xx PROFIBUS Fieldbus module Input 1 e g external reading clock Overview of pin assignment 15 pin D Sub HD plug CLV61x ECO N C N C N C TxD RS 232 HOST DC 10 30 V TxD RS 23...

Page 5: ...class III VDE 016 IEC 10110 1 Enclosure rating IP 65 DIN 40 050 EMC Radiated emission EN 61000 6 4 2007 01 A1 2011 Electromagnetic immunity EN 61000 6 2 2005 08 Vibration resistance Shock resistance EN 60068 2 6 2008 02 EN 60068 2 27 2009 05 Ambient tempera ture Operation 0 C 40 C Storage 20 C 70 C Permissible relative air humidity 90 non condensing 1 With switching outputs without load 2 Without ...

Page 6: ...ing window This effect can be avoided by using the SICK anti static plastic cleaner no 5600006 in combination with the SICK lens cloth no 4003353 Transport and Storage The CLV61x must be transported and stored in its original packaging The device must not be stored in airtight contain ers so that any residual moisture is able to escape Storage conditions dry dust free no direct sunlight 20 C 70 C ...

Reviews: