Abb. 5: Maßnahme: Isolierte Montage der Sensoren und der Peripheriegeräte/

Fig. 5: Insulated assembly of the sensors and peripheral devices

Special national regulations for Sweden and Norway
Sweden: Varning och åtjärder

Utrustning som är kopplad till skyddsjord via jordat vägguttag och/
eller via annan utrustning och samtidigt är kopplad till kabel-TV nät 
kan i vissa fall medfora risk for brand. 

  For att undvika detta skall vid anslutning av utrustningen till 

kabel-TV nät galvanisk iso lator finnas mellan utrustningen och 

kabel-TV nätet.

Norway: Advarsel og tiltaker

Utstyr som er koplet til beskyttelsesjord via nettplugg og/eller 
via annet jordtilkoplet utstyr - og er tilkoplet et kabel-TV nett, kan 
forårsake brannfare. 

  For å unngå dette skal det ved tilkopling av utstyret til kabel-TV 

nettet installeres en gal vanisk isolator mellom utstyret og kabel-
TV nettet.

Corresponding English translation

Devices which are connected to the electrical system PE of the 
building via a mains connection or other devices with a connection 
to the PE, and which are connected to a cable distribution system 
with coaxial cables, can under certain circumstances cause a risk 

of fire. Connections to a cable distribution system must therefore 

be made such that electrical insulation is offered below a certain 
frequency range (galvanic separating link).

TiM3xx

Erdungspunkt 2

grounding point 2

Erdungspunkt 3

grounding point 3

Erdungspunkt 1

grounding point 1

Erdpotenzialdifferenz/grounding potential difference

Ansteuerung für 

Schalteingänge

Trigger for 

switching inputs

Aktoren für 

Schaltausgänge

Actuators for 

switching outputs

Strom-

versorgung

Power supply

unit

U

CDB730-001

= Metallgehäuse/metal housing

= Kunststoffgehäuse/plastic housing
= geschirmte elektrische Leitung/

    shielded electrical cable 

Isolierte Montage/

electrically insulated 

Summary of Contents for CDB730-001

Page 1: ... Schraubendurchmesser 4 mm Anschlussmodul für Laserscanner TiM3xx B e t r i e b s a n l e i t u n g O p e r a t i n g I n s t r u c t i o n s Connection Module for TiM3xx Laser Scanner 1 Intended use Connection module for connecting a TiM3x laser scanner to the peripheral equipment and power supply Connect the TiM31x 32x laser scanner directly to the module Connect the TiM35x 36x laser scanner usi...

Page 2: ...gungsspannung UIN aus S 3 SGND GND Bezugspotenzial für Sensor GND ON ON Verbunden mit GND des Sensors nicht änderbar Switch Function Default S 1 Power Power supply ON ON Supply voltage UIN on OFF Supply voltage UIN off S 3 SGND GND Reference potential for sensor GND ON fixed ON Connected to sensor GND 6 Electrical Installation 6 1 Supply voltage UIN VIN Risk of injuries due to electrical current I...

Page 3: ...orking on electrical systems Connect or disconnect current linkages only under de energized conditions For wiring the switching inputs outputs of the TiM3xx use the connecting diagrams in the Technical Information TiM3xx Part no 8014318 For terminal assignment see connection diagram below or inside the cover To prevent interference do not lay cables parallel to power supply or motor cables 1 Conne...

Page 4: ... the CDB730 001 The grounding of the TiM3xx can be performed via the CDB730 001 If the peripheral devices also have metal housing and if the cable shield also lies on their housing it is assumed that all devices involved in installation have the same ground potential This is achieved for instance by mounting the devices on conductive metal surfaces correctly grounding the devices metal surfaces in...

Page 5: ...sein Abb 5 Seite 6 zeigt die Wirkungsweise dieser Maßnahme Erdschleifen werden selbst bei hohen Erdpotenzialdifferenzen wirk sam verhindert Dadurch fließen keine Ausgleichsströme mehr über die Leitungsschirme und Metallgehäuse Wichtig Die Stromversorgung für den TiM3xx sowie die angeschlossene Peripherie müssen dann ebenfalls die erforderliche Isolation sicher stellen Unter Umständen kann zwischen...

Page 6: ... ved tilkopling av utstyret til kabel TV nettet installeres en gal vanisk isolator mellom utstyret og kabel TV nettet Corresponding English translation Devices which are connected to the electrical system PE of the building via a mains connection or other devices with a connection to the PE and which are connected to a cable distribution system with coaxial cables can under certain circumstances c...

Page 7: ... C bis 40 C Einsatz nur im Zustand der Ruhe keine Montage Anschluss oder Konfigura tionsarbeiten am Modul 8 Technical Data Type CDB730 001 Part no 1055981 Visual indicators 5 x LEDs Electrical connections Female connector D Sub HD 15 pin Spring terminals 8 for cores 0 14 mm2 to 2 5 mm2 approx 26 to 13 AWG and 24 for cores 0 14 mm2 to 1 mm2 approx 26 to 17 AWG Cable glands 4 x M16 for cables 4 5 mm...

Page 8: ...one 39 02 27 43 41 E Mail info sick it Japan Phone 81 0 3 5309 2112 E Mail support sick jp Malaysia Phone 603 808070425 E Mail enquiry my sick com Netherlands Phone 31 0 30 229 25 44 E Mail info sick nl New Zealand Phone 64 9 415 0459 0800 222 278 tollfree E Mail sales sick co nz Norway Phone 47 67 81 50 00 E Mail sick sick no Poland Phone 48 22 837 40 50 E Mail info sick pl Romania Phone 40 356 1...

Reviews: