Chapter
11
Operating Instructions
C4000 Select
58
© SICK AG • Industrial Safety Systems • Germany • All rights reserved
8012247/RI61/2007-11-30
Technical specifications
Power consumption
Protective height
Sender unit
Receiver unit
Sender/receiver pair
300 mm
4.9 W
7.6 W
12.5 W
600 mm
5.3 W
7.9 W
13.2 W
900 mm
5.7 W
8.1 W
13.8 W
1200 mm
6.1 W
8.4 W
14.5 W
1500 mm
6.5 W
8.6 W
15.1 W
1800 mm
6.9 W
8.8 W
15.7 W
11.2
Response time
The response time depends on the following parameters:
number of beams
beam coding
configuration of floating blanking
number of cascaded systems
the output signal switching device used
How to determine the response time of the system:
Determine the response time of the individual components of the system.
–
The response time of a C4000 Select standalone or host system is described in sec-
tion 11.2.1 “Calculating the host/standalone response time” on page 58.
–
The response time for guest 1 using a C4000 Select system or S300/S3000 safety
laser scanner as guest 1 is described in section 11.2.2 “Calculating the guest 1
response time” on page 59.
–
The response time for guest 2 using a C4000 Select system as guest 2 is described
in section 11.2.3 “Calculating the guest 2 response time” on page 60.
You must also consider other components of the response time when performing mini-
mum safety distance calculations. Other components include, but are not limited to, safety
interfaces, safety communication networks, machine stopping time, etc. See section 5.1.1
“Minimum safety distance to the hazardous area” on page 29 for additional information.
11.2.1
Calculating the host/standalone response time
The following table provides details for C4000 Select response times based on configura-
tion with (beam code 1 or beam code 2) or without beam coding (uncoded operation). The
information presented in this table is then used to calculate the host/standalone C4000
Select response time.
Protective height
Beam Coding
300 mm
600 mm
900 mm
1200 mm
1500 mm
1800 mm
Uncoded
9 ms
11 ms
12 ms
13 ms
14 ms
15 ms
Beam code 1/2
12 ms
15 ms
18 ms
21 ms
24 ms
27 ms
Tab. 30: C4000 Select power
consumption information
Tab. 31: Response time of
the C4000 Select for applica-
tions with and without beam
coding